Del-Seal™ CF Flanges Flange Installation
|
Using clean lint free gloves, place an MDC pre-cleaned OFE copper gasket against the
knife edge seal of one of two standard Del- Seal™ CF flanges, preferably the flange
most likely to hold and support the gasket from falling. With the gasket in place arrange
mating flange with the desired bolt hole orientation. If flanges are fitted with leak test
grooves, these should be aligned. With flanges aligned, insert proper size bolt and
hand tighten.Washers are typically used on the nut side of the fastener assembly.
Repeat this procedure with the remaining bolts.
Silver plated bolts or anti-seize thread
lubricants are recommended for the
fastening of all stainless steel hardware. This
is especially true with tapped hole or blindtapped
hole mating Del-Seal™ CF flanges
which will see high temperatures. Even at
room temperatures, galling of non-lubricated
stainless steel fasteners can lead to seizing
and possible loss of a component.
|
|
|
|
After hand tightening all bolts, support bolt
and turn nut using two closed-end box
wrenches. The tightening process must be
done gradually in 1/4 to 1/2 turn increments
in a alternating crisscross pattern. Continue
this incremental tightening until the desired
torque ratings have been achieved.
Tightening bolts in this fashion will insure a
reliable seal with even gasket compression
and deformation.
|
|
|
|
|
|
|